32 Printer-Applicator-System PAM 3000
Adjusting the Sides of the Lift Cylinder Unit
At the rear side of the carrier plate of the applicator there are two screws to adjust the sides of
the cylinder unit.
1. Loosen the two screws (2) at the carrier plate of the applicator. But they may not be
removed.
2. Move the whole unit within the longish hole (1).
Adjust until the dispensed label is aligned centrally to the pad.
3. Tighten the screws (2).
Fig. 8b Side adjustment
Tuning of the Blow Tube
When applying large labels it is necessary to install a blow tube additionally.
The blow tube (2) for the supporting air can be rotated around its longitudinal axis.
By rotatinge the blow tube the direction of the air current is changed (adjusting the blow
openings to the dispense edge of the printer).
1. Loosen the lock nut (1) as well hold the slotted screw (3) with a screwdriver.
2. Adjust the tube until the air current is aligned with the dispense edge of the printer.
3. Tighten lock nut (1).
Fig. 8c Tuning the blow tube