4.4.3 Example of Changing Baud Rate
The following is a step by step example for modifying the Printer Setup.
Although this example will show how to modify only the Baud Rate
value from a default of 9600 bps to 19200 bps the same procedure can be
used to change any of the printer’s menu items.
Note: It is recommended that the Printer Setup Mode not be entered while in
Peel Mode or with the optional Present Sensor enabled. Depending on
label size this can cause unpredictable results.
1. With printer off and properly loaded with media press and hold the
button while powering up the printer. Continue to hold the button
until the PAUSED light turns off then release.
2. Press and hold the button and count 7 flashes of the FAULT light
then release. The following printout should be showing:
3. Press the button once to increment to the 19200 bps value. The
following printout should be showing:
4. At this point you will accept the current values for “test” and exit the
Printer Setup Procedure by pressing the
+
buttons
simultaneously.
Note: If you wish to discard your changes and revert back to the
previous values simply turn off power to the printer before Step 5.
5. Now you can save your changes and resume by again
pressing the
+
buttons simultaneously. Wait about 15 seconds
for
to begin.